FMOS |
---|
Iwamuro, F. (Kyoto Univ.)
Maihara, T. (Kyoto Univ.)
Akiyama, M. (Tohoku Univ.)
Kimura, M. (NAOJ)
Tamura, N. (NAOJ)
Takato, N. (NAOJ)
Tait, P. (NAOJ)
Ohta, K. (Kyoto Univ)
Eto, S. (Nikon Corp.)
Moritani, Y. (Kyoto Univ.)
Nakajima, Y. (’†“‡•ªŒõ)
FMOS specifications
|
|
IRS optical layout |
Echidna |
PFU |
in case of emergency |
IRS1 |
IRS2 |
@ | |
First Light |
|
J_long (1.13-1.35ƒÊm) |
H_short (1.40-1.60ƒÊm) |
œ Spine configuration is imperfect. œ Airglow mask is not adjusted. œ Exact focus position should be confirmed. |
|
@ | |
Blackbody test |
|
Light path |
Light path |
œ Black body source (1000Ž) œ Cassegrain hole ¨ Corrector ¨ F/2 filer ¨ F/5 fiber ¨ IRS @@@15 Lenses + 6 Mirrors + 2 Fibers + 1 Grating + 1 Filter |
|
J_long (1.13-1.35ƒÊm) |
H_short (1.40-1.60ƒÊm) |
œ Continuum + Mask pattern œ 10 subsets ~ 20 fibsers œ FWHM: 5 pixels (optical aberration: 2 pixels) œ Pitch: `10 pixels E Mask has not been blackened yet. | |
closeup view |
Airglow mask |
Wavelength dependent efficiency |
|
œ Typical efficiency: 21% (max: 30%), including Q.E. of detector @@(assuming a conversion factor of 2.1 electroms/ADU) œ Rough estimation: 0.96(15+2)x 0.986x 0.903 = 0.31 œ Almost the same efficiency as IRS2 E 1.4ƒÊm absorption originates with silica material |
|
Distribution of relative efficiencies |
Ratio of relative efficiencies |
œ Relative efficiency is distributed within factor 2 œ Typical wavelength dependency < 10% |
|
@ | |
Bright Star |
|
Defocused image of a bright star |
|
œ Meaured efficiency is 11% (max may be 16%) œ Factor `2 fainter compared to the BB measurement |
|
@ | |
Blackbody Source |
|
Surface Brightness of the Blackbody Source |
|
œ Flux is factor 1.6 higher than expected ! œ 21% / 1.6 x 0.85 (Sky & Primary) = 11% |
|
@ | |
Wavelength Calibration |
|
Extracted and distortion corrected airglow spectra | |
Airglow (@J-long band) |
|
Airglow (@H-short band) |
|
Airglow (@H-long band) |
|
Pixel - Wavelength relation |
|
œ Wavelength[ƒÊm] = 1.373 + 1.102e-4 pix - 1.314e-9 pix2 - 5.402e-14 pix3 @@@ (1ƒÐ` 1ð ` 1pixel) œ J-short image is required to determine the function @@for the full wavelength range. |
|
@ | |
Airglow Mask |
|
Extracted and distortion corrected blackbody spectra | |
Blackbody (@J-long band) |
|
Blackbody (@H-short band) |
|
Blackbody (@H-long band) |
|
œ Several vending masks should be removed. | |
@ | |
Detector |
|
Conversion Factor | |
Count image |
Noise image |
Conversion Factor map |
Count - Noise relation |
Conversion Factor |
Linearity |
œ Conversion Factor = 2.57 electrons/ADU (average) @@@@@@@@@@@`1.9 electrons/ADU (mode) œ Linearity : Correction is not needed below `40000ADU. @@@@@@@4th order correction is effective above 40000ADU. @(the gain of on-chip amp may change during the first several read out...) |
|
@ | |
Optical Alignment |
|
Mosaic Grating |
Mosaic Grating Adjustment |
œ It takes 30-60min to align the gratings. œ Long term stability has not been confirmed yet. |
|
All Observation Modes |
|
J short (0.90 - 1.13ƒÊm) |
J long (1.12 - 1.35ƒÊm) |
H short (1.40 - 1.60ƒÊm) |
H long (1.60 - 1.80ƒÊm) |
Low resolution (0.90 - 1.80ƒÊm) (This image was taken before the final vertical position adjustment.) |
|
œ 3 fibers are out of the images. œ Optical alignment is almost completed. |
|
@ | |
Raster scan |
|
Low resolution (0.90 - 1.80ƒÊm) |
Extracted 1-D spectra (0.90 - 1.80ƒÊm) |
5x5=25 0-D raster data |
Error map |
Low resolution (0.90 - 1.80ƒÊm) |
15.1mag (0.90 - 1.80ƒÊm) |
œ Typical spine error `0.2". œ 15mag, 60sec Ë S/N=5 (caused by high background). |
|
@ | |
Total efficiency |
|
High resolution (1.60 - 1.80ƒÊm) |
5x5=25 0-D raster data (bad seeing!) |
Count - mag diagram |
Total efficiency (1.60 - 1.80ƒÊm) Blue(bright) Ë Red(faint) |
œ Typical total efficiency @1.6ƒÊm: `10%. œ Somewhat worse in the J-band (should be measured again). |
|
@ | |
Mask pattern |
|
@list of masked airglow-lines | |
Summary |
|
œ System efficiency : typ. 11% - max.16% (conversion factor 2.1) @@@@@@@@@@ typ. 9% - max.13% (conversion factor 2.6) œ Airglow Mask : should be moidfied after the check by real airglow lines. œ Mosaic grating : unstable? œ 3 fibers are out of the images. œ Optical alignment is almost completed. |